Enhanced Self-Priming Pump


Enhanced Self-Priming Pump
UPM, UPS types
(PAT.)

Suction and transfer of liquid containing foam or high viscosity liquid

Top page
& Site map
Contact us


Vacuum pump built-in type UPM10-0510S (Belt drive)

Selection chart

Model number explanation
UPXXX-##@@x.****.**

XXX

: MXX: Vacuum pump built-in, SXX: Vacuum pump separate

##

: Suction/Discharge bore (cm)

@@

: Head classification

x

: S: Semi-open main impeller, N: Non-clog main impeller

****.**

: Rotation speed of main impeller, Motor output power (kW) (using normal water at normal temperature)


Enhanced Self-Priming Pump

Required power shown above is based on normal water. Please inquire regarding liquids with high viscosity or high specific gravity.

Please make sure that suction head is within 3m when using the vacuum pump built-in type under 1450min-1.



Outer dimensions

Enhanced Self-Priming Pump

Unit: mm

Model No.
Pump
Motor
Base plate
Weight
(kg)
Bore
A
B
D
E
F
S
(kW)
Pole number
G
R
J
J'
K
N
L
M
P'
Z

M10-0510S

50

440

95

185

120

219

404

1.5

4

-

520

25

20

125

600

850

370

20

15

120

M10-0510S

50

450

95

185

120

219

404

2.2

4

-

520

25

20

125

600

850

370

20

15

130

M10-0510S

50

450

95

185

120

219

404

3.7

4

-

520

25

20

125

600

850

370

20

15

140

M10-0510S

50

450

95

185

120

219

404

5.5

4

-

520

25

20

125

600

850

370

20

15

160

M10-0510S

50

470

95

185

120

219

404

7.5

4

-

520

25

20

125

600

850

370

20

15

170

Flange standard is JIS 10K.

We also provide handle hose couplers.



Features
Structure
Technical data
Selection & Dimensions
Inquiry form