Technical data
Flange standard dimensions
|
Standard JIS 10K FF type
|
Waterworks standard
|
|

|

|
|
Nominal
bore
|
JIS 10K, JIS B2239
|
Waterworks standard, JIS B2062
|
|
A
|
D
|
C
|
n-h
|
Bolt
|
(f)
|
(g)
|
D
|
C
|
n-h
|
Bolt
|
(f)
|
(g)
|
|
25
|
125
|
90
|
4-19
|
M16
|
1
|
67
|
Based on JIS 10K
|
|
32
|
135
|
100
|
4-19
|
M16
|
2
|
76
|
Based on JIS 10K
|
|
40
|
140
|
105
|
4-19
|
M16
|
2
|
81
|
Based on JIS 10K
|
|
50
|
155
|
120
|
4-19
|
M16
|
2
|
96
|
Based on JIS 10K
|
|
65
|
175
|
140
|
4-19
|
M16
|
2
|
116
|
Based on JIS 10K
|
|
80
|
185
|
150
|
8-19
|
M16
|
2
|
126
|
211
|
168
|
4-19
|
M16
|
3
|
125
|
|
100
|
210
|
175
|
8-19
|
M16
|
2
|
151
|
238
|
195
|
4-19
|
M16
|
3
|
152
|
|
125
|
250
|
210
|
8-23
|
M20
|
2
|
182
|
263
|
220
|
6-19
|
M16
|
3
|
177
|
|
150
|
280
|
240
|
8-23
|
M20
|
2
|
212
|
290
|
247
|
6-19
|
M16
|
3
|
204
|
|
200
|
330
|
290
|
12-23
|
M20
|
2
|
262
|
342
|
299
|
8-19
|
M16
|
3
|
256
|
|
250
|
400
|
355
|
12-25
|
M22
|
2
|
324
|
410
|
360
|
8-23
|
M20
|
3
|
308
|
|
300
|
445
|
400
|
16-25
|
M22
|
3
|
368
|
464
|
414
|
10-23
|
M20
|
4
|
362
|
|
350
|
490
|
445
|
16-25
|
M22
|
3
|
413
|
530
|
472
|
10-25
|
M22
|
4
|
414
|
|
400
|
560
|
510
|
16-27
|
M24
|
3
|
475
|
582
|
524
|
12-25
|
M22
|
4
|
466
|
|
450
|
620
|
565
|
20-27
|
M24
|
3
|
530
|
652
|
586
|
12-27
|
M24
|
4
|
518
|
|
500
|
675
|
620
|
20-27
|
M24
|
3
|
585
|
706
|
639
|
12-27
|
M24
|
4
|
572
|
|
600
|
795
|
730
|
24-33
|
M30
|
3
|
690
|
810
|
743
|
16-27
|
M24
|
4
|
676
|
|
Note:
|
|

|
We manufacture valves with RF flanges (dimensions f, g ) for JIS 10K pipe
flanges upon request.
|
|

|
The flange thickness is based on our standard.
|
|
Piping examples
|
|
Installation in horizontal piping is standard.
Please contact us about installation in vertical piping.
|
|
1.
|
Standard piping example
|
|
(1)
|
It is not necessary to install a straight pipe at the rear of the Constant
Flow Regulator Valve.
When install a gate valve at the front of the Constant Flow Regulator Valve,
install a straight pipe as shown.
If you plan to install a flow meter, please install the designated straight
pipe.
|

D=Nominal bore
|
|
(2)
|
Install a piping within an angle of +/-3 degrees.
|
|
|
2.
|
When there is a bent pipe on the inlet side:
|
|
(1)
|
When the bent pipe is parallel to the valve shaft:
It is not necessary to install a straight pipe at the front or the rear
of the valve.
|
|
|
(2)
|
When the bent pipe is perpendicular to the valve shaft:
Install a straight pipe as shown.
|

D=Nominal bore
|
|
Installation examples
|
|
|
1. Unit protection equipped
|
|
|

|
|
Bore
|
A
|
B
|
C
|
D
|
E
|
F
|
T
|
H
|
L
|
|
50
|
400
|
800
|
600
|
1500
|
150
|
195
|
125
|
2145
|
2250
|
|
80
|
400
|
800
|
600
|
1500
|
150
|
195
|
125
|
2145
|
2250
|
|
100
|
400
|
800
|
600
|
1500
|
150
|
195
|
125
|
2145
|
2250
|
|
150
|
400
|
800
|
600
|
1500
|
150
|
195
|
125
|
2145
|
2250
|
|
200
|
400
|
1100
|
900
|
1800
|
250
|
295
|
160
|
2945
|
2650
|
|
250
|
400
|
1100
|
900
|
1800
|
250
|
295
|
160
|
2945
|
2650
|
|
300
|
450
|
1050
|
900
|
2200
|
280
|
295
|
190
|
2975
|
3100
|
|
350
|
500
|
1000
|
900
|
2200
|
280
|
295
|
190
|
2975
|
3100
|
On-site construction time can be reduced by use of a ready-made knockdown
manhole for protective construction. (Dimension C is changeable.) The above
dimensions are in accordance with the National Uni-hole Industrial Association
Standard.
|
|
2. On-site protection construction
|
|
|

|
|
Bore
|
A
|
B
|
H
|
L
|
|
50
|
400
|
1500
|
1400
|
1200
|
|
80
|
400
|
1500
|
1400
|
1300
|
|
100
|
400
|
1500
|
1400
|
1400
|
|
150
|
400
|
1500
|
1400
|
1550
|
|
200
|
400
|
1500
|
1400
|
1800
|
|
250
|
400
|
1600
|
1500
|
2000
|
|
300
|
450
|
1600
|
1700
|
2200
|
|
350
|
500
|
1600
|
1800
|
2400
|
|
400
|
550
|
1900
|
2000
|
2500
|
|
450
|
750
|
1900
|
2500
|
2800
|
|
500
|
750
|
1900
|
2500
|
3000
|
|
600
|
800
|
2000
|
2700
|
3200
|
|
|

|
Specifications stated here may be subject to change without notice due
to product improvement.
|
|