| Technical data
Flange standard dimensions
| Standard JIS 10K FF type | Waterworks standard | 
| 
|
|
Nominal bore | JIS 10K, JIS B2239 | Waterworks standard, JIS B2062 | | A | D | C | n-h | Bolt | (f) | (g) | D | C | n-h | Bolt | (f) | (g) | 25 | 125 | 90 | 4-19 | M16 | 1 | 67 | Based on JIS 10K | 32 | 135 | 100 | 4-19 | M16 | 2 | 76 | Based on JIS 10K | 40 | 140 | 105 | 4-19 | M16 | 2 | 81 | Based on JIS 10K | 50 | 155 | 120 | 4-19 | M16 | 2 | 96 | Based on JIS 10K | 65 | 175 | 140 | 4-19 | M16 | 2 | 116 | Based on JIS 10K | 80 | 185 | 150 | 8-19 | M16 | 2 | 126 | 211 | 168 | 4-19 | M16 | 3 | 125 | 100 | 210 | 175 | 8-19 | M16 | 2 | 151 | 238 | 195 | 4-19 | M16 | 3 | 152 | 125 | 250 | 210 | 8-23 | M20 | 2 | 182 | 263 | 220 | 6-19 | M16 | 3 | 177 | 150 | 280 | 240 | 8-23 | M20 | 2 | 212 | 290 | 247 | 6-19 | M16 | 3 | 204 | 200 | 330 | 290 | 12-23 | M20 | 2 | 262 | 342 | 299 | 8-19 | M16 | 3 | 256 | 250 | 400 | 355 | 12-25 | M22 | 2 | 324 | 410 | 360 | 8-23 | M20 | 3 | 308 | 300 | 445 | 400 | 16-25 | M22 | 3 | 368 | 464 | 414 | 10-23 | M20 | 4 | 362 | 350 | 490 | 445 | 16-25 | M22 | 3 | 413 | 530 | 472 | 10-25 | M22 | 4 | 414 | 400 | 560 | 510 | 16-27 | M24 | 3 | 475 | 582 | 524 | 12-25 | M22 | 4 | 466 | 450 | 620 | 565 | 20-27 | M24 | 3 | 530 | 652 | 586 | 12-27 | M24 | 4 | 518 | 500 | 675 | 620 | 20-27 | M24 | 3 | 585 | 706 | 639 | 12-27 | M24 | 4 | 572 | 600 | 795 | 730 | 24-33 | M30 | 3 | 690 | 810 | 743 | 16-27 | M24 | 4 | 676 |
Note: | 
| We manufacture valves with RF flanges (dimensions f, g ) for JIS 10K pipe flanges upon request. | 
| The flange thickness is based on our standard. |
Piping examples | Installation in horizontal piping is standard. Please contact us about installation in vertical piping. | 1. | Standard piping example | | (1) | It is not necessary to install a straight pipe at the rear of the Constant Flow Regulator Valve. When install a gate valve at the front of the Constant Flow Regulator Valve, install a straight pipe as shown. If you plan to install a flow meter, please install the designated straight pipe. |  D=Nominal bore | | (2) | Install a piping within an angle of +/-3 degrees. |  | 2. | When there is a bent pipe on the inlet side: | | (1) | When the bent pipe is parallel to the valve shaft: It is not necessary to install a straight pipe at the front or the rear of the valve. |  | | (2) | When the bent pipe is perpendicular to the valve shaft: Install a straight pipe as shown. |  D=Nominal bore
|
Installation examples | | 1. Unit protection equipped | | 
|
| Bore | A | B | C | D | E | F | T | H | L | 50 | 400 | 800 | 600 | 1500 | 150 | 195 | 125 | 2145 | 2250 | 80 | 400 | 800 | 600 | 1500 | 150 | 195 | 125 | 2145 | 2250 | 100 | 400 | 800 | 600 | 1500 | 150 | 195 | 125 | 2145 | 2250 | 150 | 400 | 800 | 600 | 1500 | 150 | 195 | 125 | 2145 | 2250 | 200 | 400 | 1100 | 900 | 1800 | 250 | 295 | 160 | 2945 | 2650 | 250 | 400 | 1100 | 900 | 1800 | 250 | 295 | 160 | 2945 | 2650 | 300 | 450 | 1050 | 900 | 2200 | 280 | 295 | 190 | 2975 | 3100 | 350 | 500 | 1000 | 900 | 2200 | 280 | 295 | 190 | 2975 | 3100 | On-site construction time can be reduced by use of a ready-made knockdown manhole for protective construction. (Dimension C is changeable.) The above dimensions are in accordance with the National Uni-hole Industrial Association Standard.
| 2. On-site protection construction | | 
|
| Bore | A | B | H | L | 50 | 400 | 1500 | 1400 | 1200 | 80 | 400 | 1500 | 1400 | 1300 | 100 | 400 | 1500 | 1400 | 1400 | 150 | 400 | 1500 | 1400 | 1550 | 200 | 400 | 1500 | 1400 | 1800 | 250 | 400 | 1600 | 1500 | 2000 | 300 | 450 | 1600 | 1700 | 2200 | 350 | 500 | 1600 | 1800 | 2400 | 400 | 550 | 1900 | 2000 | 2500 | 450 | 750 | 1900 | 2500 | 2800 | 500 | 750 | 1900 | 2500 | 3000 | 600 | 800 | 2000 | 2700 | 3200 |
| 
|